Geosynthetic Clay Liners (GCLs)

A few millimeters of bentonite can perform like a thick clay layer, provided the bentonite stays swollen. Understanding why is the key to using GCLs well.

What a GCL is

A GCL is a factory-made blanket of granular or powdered sodium bentonite held between two geotextiles by needle-punching or stitching, or glued to a geomembrane. Rolls are unrolled and overlapped on site, often with supplemental bentonite in the overlaps.

Why bentonite seals

Bentonite is dominated by montmorillonite, a smectite clay mineral. Sodium montmorillonite in fresh water undergoes osmotic swelling: water enters between the clay platelets, and the swollen gel fills pores and makes flow paths extremely tortuous. With dilute water, needle-punched GCLs commonly show hydraulic conductivities around 10−11 m/s.

Chemical compatibility

Swelling depends on the liquid. Solutions with high ionic strength or many divalent cations (calcium, magnesium) suppress osmotic swelling and, over time, calcium can replace sodium on the clay’s exchange sites. The result can be a hydraulic conductivity that is one or more orders of magnitude higher. Liquids of concern include some coal combustion product leachates, mine drainage, seawater and certain industrial leachates.

  • Test with the real liquid. Long-term permeation with site-specific or simulated leachate, continued until chemical equilibrium, is far more informative than a short test with water.
  • Prehydration helps. Hydrating the GCL with clean water from the subgrade before it contacts leachate can preserve low conductivity, but it is not a guarantee.
  • Enhanced bentonites (polymer-amended) can improve compatibility, but performance varies by product and liquid and must be verified.

Field issues

  • Panel shrinkage: exposed GCLs under a black geomembrane can shrink through wet–dry cycles and open overlaps. Cover promptly and use generous overlaps.
  • Low confining stress: conductivity is higher at low effective stress, as in covers.
  • Desiccation and cation exchange in covers can raise conductivity over years.
  • Internal and interface shear strength: hydrated bentonite is weak; reinforced GCLs and stability analyses are essential on slopes.

Relevant test methods

ASTM D5887 (index flux through saturated GCL specimens), ASTM D6766 (hydraulic properties of GCLs permeated with potentially incompatible liquids), ASTM D5890 (swell index) and ASTM D5084 (flexible-wall hydraulic conductivity) are commonly cited. See the reading list.

Keep learning

Glossary