Why 1×10⁻⁷ cm/s? The Story Behind the Clay Liner Standard

Where the familiar hydraulic conductivity limit for compacted clay liners comes from, and what it does and does not guarantee.

Anyone who has specified a compacted clay liner has met the number 1×10−7 cm/s. It appears in US federal rules for municipal and coal-ash landfills and in many state and international codes. Why that value?

A practical threshold

The figure became a regulatory default in the 1980s as a level that well-compacted clayey soils could reliably achieve and that, combined with a thickness of about 2 ft (0.6 m) and a low head, kept advective seepage small. It was a constructability benchmark as much as a performance target.

What it does not cover

  • Field vs. lab: small laboratory specimens often show lower conductivity than the field-scale liner, where clods, lift interfaces and cracks dominate. Large-scale field tests, such as sealed double-ring infiltrometers, give more representative values.
  • Diffusion: a liner meeting the limit can still pass contaminants by diffusion, especially if thin.
  • Durability: desiccation, freeze–thaw and chemical attack can raise conductivity after construction.

The takeaway

Treat 1×10−7 cm/s as a minimum quality marker, not a performance guarantee. Real performance comes from the whole system: low head, composite action, adequate thickness and good construction. Read more in liner systems.