Anyone who has specified a compacted clay liner has met the number 1×10−7 cm/s. It appears in US federal rules for municipal and coal-ash landfills and in many state and international codes. Why that value?
A practical threshold
The figure became a regulatory default in the 1980s as a level that well-compacted clayey soils could reliably achieve and that, combined with a thickness of about 2 ft (0.6 m) and a low head, kept advective seepage small. It was a constructability benchmark as much as a performance target.
What it does not cover
- Field vs. lab: small laboratory specimens often show lower conductivity than the field-scale liner, where clods, lift interfaces and cracks dominate. Large-scale field tests, such as sealed double-ring infiltrometers, give more representative values.
- Diffusion: a liner meeting the limit can still pass contaminants by diffusion, especially if thin.
- Durability: desiccation, freeze–thaw and chemical attack can raise conductivity after construction.
The takeaway
Treat 1×10−7 cm/s as a minimum quality marker, not a performance guarantee. Real performance comes from the whole system: low head, composite action, adequate thickness and good construction. Read more in liner systems.