GCLs perform best with dilute liquids. When the containment target is coal-ash leachate, mining solutions or industrial waste, run through this checklist.
- What is the liquid’s ionic strength and the ratio of monovalent to divalent cations? High ionic strength and abundant divalent cations are red flags.
- Is there representative leachate chemistry, including variability over time?
- Will the GCL be prehydrated from the subgrade before contact, and under what stress?
- What effective stress will act on it? Covers and pond side slopes are low-stress cases.
- Is long-term testing with the actual liquid planned, run until termination criteria for chemical equilibrium are met?
- Is a polymer-enhanced bentonite proposed? Verify the specific product with the specific liquid.
- What does the design rely on if the GCL’s conductivity rises? Composite action with a geomembrane and a low-head drainage layer provide redundancy.
Background: how GCLs work.